Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Arq. bras. oftalmol ; 86(5): e20230064, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1513681

RESUMO

ABSTRACT Purpose: The study aimed to evaluate the clinical and tissue response to a hollow polymethylmethacrylate orbital implant with a multiperforated posterior surface in an animal model after evisceration. Methods: Sixteen New Zealand rabbits had their right eye eviscerated. All animals received a hollow polymethylmethacrylate implant 12 mm in diameter that is multiperforated in its posterior hemisphere. The animals were divided into four groups, and each one had the eye exenterated at 7, 30, 90, and 180 days post-evisceration. Clinical signs were assessed daily for 14 days post-evisceration and then every 7 days until 180 days. Inflammatory pattern, collagen structure, and degree of neovascularization generated with implant placement were analyzed with hematoxylin-eosin, picrosirius red, and immunohistochemistry staining. Results: There were no signs of infection, conjunctival or scleral thinning, or implant exposure or extrusion in any animal during the study. On day 7, the new tissue migrated into the implant and formed a fibrovascular network through the posterior channels. Inflammatory response reduced over time, and no multinuclea­ted giant cells were found at any time. Conclusion: Hollow polymethylmethacrylate orbital implants with a multiperforated posterior surface enable rapid integration with orbital tissues by fibrovascular ingrowth. We believe that this orbital implant model can be used in research on humans.


RESUMO Objetivo: Avaliar a resposta tecidual e clínica a um implante orbitário de polimetilmetacrilato, oco e multiperfu­rado em sua porção posterior em modelo animal após evisceração. Métodos: Dezesseis coelhos da raça Nova Zelândia foram submetidos à evisceração do globo ocular direito. Todos receberam implante oco de polimetilmetacrilato de 12 mm de diâmetro, multiperfurado em sua semiesfera posterior. O estudo foi dividido em avaliação clínica e histopatológica. A avaliação clínica foi diária até 14 dias pós-evisceração e, a cada sete dias, até completar 180 dias. Os animais foram divididos em grupos de quatro animais e cada um foi submetido à exenteração com 07, 30, 90 e 180 dias e depois à eutanásia. A análise histopatológica teve por fim caracterizar o padrão inflamatório, a estrutura do colágeno e o grau de neovascularização. Para isso, além da tradicional coloração pela hematoxilina-eosina, utilizou-se o corante Picrosirius Red (PSR) e imuno-histoquímica com o marcador CD 34. Resultados: Não houve sinais de infecção, afinamento conjuntival ou escleral, exposição ou extrusão do implante em nenhum animal durante o estudo. Já no sétimo dia, o tecido neoformado migrou para dentro do implante formando uma rede fibrovascular através dos canais posteriores. A resposta inflamatória diminuiu ao longo do tempo avaliado e não foram encontradas células gigantes multinucleadas. Conclusão: O implante analisado permite a sua integração aos tecidos orbitários pelo crescimento fibrovascular em seu interior. Os autores acreditam que este modelo de implante orbital pode fazer parte de testes com humanos.

2.
Cir. plást. ibero-latinoam ; 48(3): 287-304, jul.-sep. 2022. ilus
Artigo em Espanhol | IBECS | ID: ibc-211342

RESUMO

La enfermedad por rellenos sintéticos permanentes (EIRSP) representa un verdadero problema de salud pública sobre todo en América Latina, afectando a millones de personas, predominantemente mujeres de mediana edad de estrato económico medio-bajo. Actualmente no existe una conducta terapéutica consensuada, razón que motivó al Comité de Biomateriales de la FILACP 2020-2022 a crear un grupo de 9 expertos quienes se plantearon los siguientes objetivos: 1.- Resaltar la importancia de la enfermedad, 2.- Clasificar sus estadios clínicos, 3.- Proponer un protocolo integral de diagnóstico y tratamiento, 4.- Proponer una estrategia terapéutica multidisciplinaria y 5.- Promover campañas de prevención.El relleno sintético más utilizado con fines estéticos ha sido la silicona inyectada en cara, glúteos, mamas, miembros inferiores, manos y genitales, con alto potencial de migración. Otras substancias son el metacrilato, aceites minerales, parafina y la combinación de ellas. Ninguno de estos productos es de grado médico ni biocompatible. Al ser inyectados van a producir diversas reacciones locales y sistémicas desencadenadas por reacción de hipersensibilidad tipo IV, conduciendo al desarrollo de una enfermedad autoinmune de tejido conectivo.Se propone una clasificación basada en 6 estadios clínicos o grados. 1: Sin signos ni síntomas. 2: Cambios de coloración. 3: Inflamación, induraciones, cambios de textura y dolor. 4: Extrusión del producto con o sin infección. 5: Migración. 6: Complicaciones locales o sistémicas graves.Se establecen las pautas diagnósticas basadas en la historia clínica, exámenes de laboratorio, inmunológicos y radiológicos. Para este último, la resonancia magnética es la técnica de elección y en algunos casos, con excepción de glúteos y mamas, el ultrasonido es de gran utilidad. (AU)


Disease caused by permanent synthetic fillers (EIRSP acronym in Spanish) represents a real public health problem, especially in Latin America, affecting millions of people, predominantly middle-aged women from a medium-low economic stratum. Currently, there is no consensual therapeutic behavior, the reason that motivated the FILACP Biomaterials Committee 2020-2022 to create a group of 9 experts, who set the following objectives: 1.- Highlight the importance of the disease, 2.- Classify the clinical stages, 3.- Propose a comprehensive diagnosis and treatment protocol, 4.- Propose a multidisciplinary therapeutic strategy and 5.- Promote prevention campaigns.The most widely used synthetic filler for aesthetic purposes has been silicone injected into the face, buttocks, breasts, lower limbs, hands and genitals, with a high potential for migration. Other substances are methacrylate, mineral oils, paraffin, and a combination. None of these products have a medical grade or are biocompatible. When injected, they will produce various local and systemic reactions triggered by type IV hypersensitivity reactions, leading to the development of autoimmune connective tissue disease.A classification based on 6 clinical stages or grades is proposed. 1: No signs or symptoms. 2: Color changes. 3: Inflammation, indurations, texture changes, and pain. 4: Extrusion of the product with or without infection. 5: Migration. 6: Severe local or systemic complications.Diagnostic guidelines are established based on clinical history, laboratory, immunological and radiological tests. For the latter, magnetic resonance imaging is the technique of choice, and in some cases, except for the buttocks and breasts, ultrasound is beneficial. (AU)


Assuntos
Humanos , Cirurgia Plástica , Materiais Biocompatíveis , Próteses e Implantes , Géis de Silicone , Polimetil Metacrilato
3.
Rev.chil.ortop.traumatol. ; 63(1): 33-39, apr.2022. ilus, tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1435965

RESUMO

OBJETIVO Identificar la tasa de recurrencia de tumor de células gigantes (TCG) en pacientes tratados con curetaje y cementación con seguimiento mínimo de tres años. MATERIALES Y METODOS Cohorte retrospectiva y observacional de pacientes con diagnóstico de TCG en estadios 1 y 2 de Enneking tratados con curetaje intralesional y cementación entre 1981 y 2011. Se registraron edad, sexo, región anatómica, y tiempo de recurrencia. Se utilizó estadística descriptiva con medidas de tendencia central y medidas de dispersión (desviación estándar) para variables cuantitativas, y porcentajes para variables cualitativas. RESULTADOS Entre 1981 y 2011, se identificaron 375 casos de TCG, de los cuales 141 (37,6%) fueron tratados con este método. El seguimiento fue de 48 a 240 meses, y la edad, de 27 9 años; 45% de los pacientes eran mujeres, y 55%, varones, con una relación mujer:hombre de 1,2:1. El hueso más afectado fue la tibia (38%), seguida del fémur (32%), del húmero (16%), y del radio (10%). En 88,6%, la resección fue curetaje intralesional, y el resto, marginal. Hubo 15,7% de casos de TCG con fractura, y recidiva en 12,7%. DISCUSIÓN Se ha demostrado que este método de tratamiento reduce el riesgo de recurrencia por los efectos adyuvantes locales de la cementación acrílica. La recurrencia ocurre en los dos primeros años de seguimiento. Sin embargo, hay autores que respaldan que el margen quirúrgico es el único factor que influencia el riesgo de recurrencia local. La extensión extraósea del TCG no es contraindicación para curetaje intralesional y adyuvante con metilmetacrilato. CONCLUSIONES Reportamos tasa una de recurrencia similar a la de la literatura, siendo un recurso factible de reconstrucción de miembros


OBJETIVE To identify the recurrence rate of giant-cell tumor (GCT) in patients treated by curetage and adjuvant therapy with polymethil metacrylate with a minimum followup of 3 years. MATERIALS AND METHODS Observational and retrospective cohort with patients with diagnoses of Enneking stages 1 and 2 GCT treated through intralesional curetage and cementation between 1981 and 2011. Age, gender, anatomic location and relapse period were recorded. The data was analyzed with measures of central tendency and dispersion (standard deviation) for the quantitative variables, percentages for the qualitative variables. RESULTS Between 1981 and 2011 375 cases of GCT were identified, 141 (36.7%) of which were treated by this method. The follow-up ranged from 48 to 240 months, the age was of 27 9 years, 45% of the patients were female, and 55%, male, with a female: male ratio of about 1.2:1. The tibia was the most frequent affected bone (38%), followed by the femur (32%), the humerus (16%), and the radius (10%). The resection thecnique was intralesional curetage in about 88.6% of the cases, and marginal resection in the remaining cases. Pathologic fracture was present in approximately 15.7%, and recurrence occurred in approximately 12.7%. DISCUSSION We demonstrated that this treatment method decreases the risk of recurrence due to the local adjuvant effects of acrylic cementation. Recurrence events occur in the first two years after resection. However, some authors defend that the surgical margin is the only factor that influences the risk of local recurrence. The extraosseus extension of GCT is not a contraindication to perform intralesional curetage or to prescribe the adjuvant treatment with polymethyl metacrylate. CONCLUSIONS We reported a recurrence rate similar to that of the literature, and this is a feasible resource for limb reconstruction


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Cimentação/métodos , Curetagem/métodos , Tumores de Células Gigantes/cirurgia , Tumores de Células Gigantes/epidemiologia , Recidiva , Epidemiologia Descritiva
4.
Odontol. Sanmarquina (Impr.) ; 25(2): e21098, abr.-jun. 2022.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1368407

RESUMO

En este artículo se muestra que es posible realizar una prótesis digital con polimetilmetacrilato (PMMA) de forma sencilla con programas gratuitos y una impresora 3D de bajo costo y de fácil manejo. El caso clínico corresponde a un masculino de 38 años de edad quien refiere haber sido operado de urgencia por un hematoma subdural de origen traumático, secundario a una caída desde un andamio de 5 metros de altura, por parte del Servicio de Neurocirugía con una craneotomía descompresiva 10 meses atrás, actualmente presentando un defecto en región supraorbitaria y frontal bilateral y refiriendo cefaleas y mareos constantes con diagnóstico de síndrome del trefinado. Se decide diseñar digitalmente una prótesis con PMMA colocándola bajo anestesia general balanceada en quirófano mediante un acceso coronal, fijándola con tornillos de titanio y reposicionando tejidos con suturas. Se logra eliminar de forma inmediata el defecto visual, la sintomatología desapareció por completo confirmándolo en los controles desde los 7 días. Se muestra que es posible realizar una prótesis craneal personalizada de bajo costo de forma sencilla, resolviendo las molestias y eliminando las secuelas y complicaciones que afectan a los pacientes tratados por craniectomías descompresivas con presencias de defectos.


In this aticle it is showns that it is possible to make a digital prosthesis with Polymethylmethacrylate (PMMA) with free programs and a low-cost and easy-to-use 3D printer. The clinical case corresponds to a 38-year-old male who reported having undergone emergency surgery for a subdural hematoma of traumatic origin, secondary to a fall from a 5-meter-high scaffolding, procedure done by the Neurosurgery Service with a decompressive craniotomy 10 months ago, nowadays he presents a bilateral defect at the supraorbital and frontal region, referring constant headaches and dizziness with a diagnosis of a trephination syndrome. We decided to digitally design a prosthesis with PMMA, placing it under balanced general anesthesia in the operating room through a coronal approach, fixing it with titanium screws and repositioning tissues with sutures. The visual defect was immediately eliminated, the symptoms disappeared completely, confirming it at the controls since day 7. It is shown that it is possible to perform a low-cost personalized cranial prosthesis in a simple way, solving the discomfort and eliminating the sequelae and complications that affect patients treated by decompressive craniectomies with the presence of defects.

5.
Rev. bras. ortop ; 56(6): 772-776, Nov.-Dec. 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1357139

RESUMO

Abstract Objective To evaluate the better potential and functional results in pain control in the treatment of pathological fractures and prophylactic fixation with an intramedullary nail associated with polymethylmethacrylate, compared with the utilization of an intramedullary nail in long bone tumor lesions. Methods From January 2012 to September 2017, 38 patients with 42 pathological lesions (fractures or impending fractures according to the Mirels criteria) were treated surgically. Sixteen patients allocated to the control group underwent a locked intramedullary nail fixation, and 22 patients with pathological lesions were allocated to treatment with an intramedullary nail associated with polymethylmethacrylate. Postoperatively, the patients were submitted to the Musculoskeletal Tumor Society (MSTS) rating scale, radiographic assessment, and to the assessment of events and complications related to the treatment. Results The evaluation using the MSTS questionnaire showed better functional results in the group associated with polymethylmethacrylate, in comparison with the control group, which obtained an average score of 16.375 out of a maximum of 30 points (54.6%). The group studied with association with polymethylmethacrylate obtained a mean of 22.36 points (74.5%). The procedure proved to be safe, with similar complication and severity rates, and with no statistical difference in comparison with the standard treatment. Conclusion Stabilization of tumor lesions with an internal fixation associated with the polymethylmethacrylate demonstrated early rehabilitation and improved the quality of life, allowing rapid functional recovery. The use of polymethylmethacrylate has advantages such as reduced bleeding, tumor necrosis and higher mechanical stability.


Resumo Objetivo Avaliar o potencial melhor resultado funcional e controle álgico no tratamento de fraturas patológicas e fixações profiláticas tratadas com haste intramedular associada ao polimetilmetacrilato (PMMA) em comparação com o uso de haste intramedular em lesões tumorais em ossos longos. Métodos De janeiro de 2012 a setembro de 2017, 38 pacientes com 42 lesões patológicas (fraturas ou iminência segundo os critérios de Mirels) foram tratados cirurgicamente. Dezesseis pacientes submetidos a fixação com haste intramedular bloqueada foram alocados ao grupo controle e 22 pacientes com lesões patológicas foram alocados para tratamento com haste intramedular associada ao PMMA. No pósoperatório, foi realizada a submissão dos pacientes ao escore da Musculoskeletal Tumor Society (MSTS, na sigla em inglês) e à avaliação radiográfica do tratamento realizado, assim como à avaliação de intercorrências e complicações relacionadas ao tratamento. Resultados A avaliação através do questionário MSTS demonstrou melhor resultado funcional do grupo associado com PMMA quando comparado com o grupo controle, o qual obteve uma pontuação média de 16,375 em um máximo de 30 pontos (54,6%), enquanto o grupo em estudo com associação do PMMA obteve uma média de 22,36 pontos (74,5%). O procedimento mostrou-se seguro, taxas de complicações e gravidade semelhantes e sem diferença estatística quando comparado com o tratamento padrão. Conclusão A estabilização de lesões tumorais com fixação associada ao PMMA demonstrou reabilitação precoce e melhora na qualidade de vida, permitindo rápida recuperação funcional. A utilização do PMMA apresenta vantagens como diminuição do sangramento e da necrose tumoral e maior estabilidade mecânica.


Assuntos
Humanos , Qualidade de Vida , Cimentos Ósseos , Neoplasias Ósseas , Inquéritos e Questionários , Polimetil Metacrilato , Fixação Intramedular de Fraturas , Fraturas Espontâneas
6.
Rev. Odontol. Araçatuba (Impr.) ; 42(2): 52-55, maio-ago. 2021. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1283891

RESUMO

Pacientes com históricos de defeitos ósseos provocados por infecções, malformação congênita, neoplasias, deformação por iatrogenia, radioterapia e trauma buscam contornos faciais mais harmônicos através da reabilitação cirúrgica. Para facilitar a reconstrução maxilofacial dois grupos de materiais podem ser utilizados, os enxertos ósseos e os materiais aloplásticos. O objetivo é relatar um caso incomum de infecção e exposição de material utilizado para enxertia a base de polimetilmetacrilato, bem como a sua posterior reabordagem cirúrgica. Embora o Polimetilmetacrilato aparente ser seguro, ele exibe complicações diversas em função da imunologia do hospedeiro, que poderá reagir de diferentes formas. Desse modo, faz-se necessário ressaltar a importância da prevenção e proservação de cada caso de forma individualizada(AU)


Patients with a history of bone defects caused by infections, congenital malformation, neoplasms, iatrogenic deformation, radiotherapy and trauma seek more harmonious facial contours through surgical rehabilitation. To facilitate maxillofacial reconstruction, two groups of materials can be used, bone grafts and alloplastic materials. The objective is to report an unusual case of infection and exposure of material used for grafting with polymethylmethacrylate, as well as its subsequent surgical approach. Although Polymethylmethacrylate appears to be safe, it exhibits different complications depending on the host's immunology, which may react in different ways. Thus, it is necessary to emphasize the importance of preventing and preserving each case individually(AU)


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Transplante Ósseo , Polimetil Metacrilato , Traumatismos Maxilofaciais , Órbita , Cirurgia Bucal , Zigoma , Materiais Biocompatíveis , Doença Iatrogênica , Maxila
7.
Braz. dent. sci ; 24(3): 1-7, 2021. tab, ilus
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1281904

RESUMO

Objective: The aim of the study was to fabricate and morphologically characterize ultrafine Polyetherimide fibers (PEI) associated with Polymethylmethacrylate (PMMA) ­ PP (group formed by the association of PEI with PMMA), produced by the electrospinning process. Material and Methods: A solution of PEI (0.562 g) + PMMA (0.377 g) dissolved in 2.5 mL of chloroform, 0.85 mL of Dimethylformamide (DMF) and 0.85 mL of 1.1.2.2 Tetrachloroethane (TCE) was prepared. For the electrospinning process, different continuous voltages (10 to 18 kV) and two different distances (8 and 12 cm) between the needle tip and the collecting apparatus were used, giving rise to 6 distinct groups of ultrafine fibers (PP 1 to 6) that were observed in Scanning Electron Microscopy to check for defects and calculate the average diameter of the fibers. Results: The best parameter, the parameter that was most effective for the production of fibers, observed was subjected to Energy Dispersion X-ray Spectroscopy (EDS), X-ray Diffraction (XRD) and Contact Angle Analysis tests. The data were analyzed using the ANOVA and Tukey test (p <0.05). From the comparative analysis of the pre-established parameters, the pattern of PP4 ultrafine fibers was shown to be more effective. Conclusion: The PP4 standard (13 kV ­ 12 cm) had an average diameter of 0.37 µm. An adequate parameter to electrospinning was able to produce ultrafine fibers of PMMA/PEI (AU)


Introdução: O objetivo do estudo foi sintetizar e caracterizar morfologicamente fibras ultrafinas de Polieterimida (PEI) associadas ao Polimetilmetacrilato (PMMA) - PP (grupo formado pela associação de PEI com PMMA), produzidas pelo processo de eletrofiação. Material e Métodos: Foi preparada uma solução de PEI (0,562 g) + PMMA (0,377 g) dissolvido em 2,5 mL de clorofórmio, 0,85 mL de Dimetilformamida (DMF) e 0,85 mL de 1.1.2.2 Tetracloroetano (TCE). Para o processo de eletrofiação, foram utilizadas diferentes tensões contínuas (10 a 18 kV) e duas distâncias diferentes (8 e 12 cm) entre a ponta da agulha e o aparelho coletor, dando origem a 6 grupos distintos de fibras ultrafinas (PP 1 a 6) que foram observados em Microscopia Eletrônica de Varredura para verificar defeitos e calcular o diâmetro médio das fibras. Resultados: O melhor parâmetro, o parâmetro mais eficaz para a produção de fibras, observado foi submetido aos testes de Espectroscopia de Dispersão de Energia (EDS), Difração de Raios X (DRX) e Análise do Ângulo de Contato. Os dados foram analisados pela ANOVA e teste de Tukey (p <0,05). A partir da análise comparativa dos parâmetros pré-estabelecidos, o padrão das fibras ultrafinas PP4 mostrou-se mais eficaz. Conclusão: O padrão PP4 (13 kV - 12 cm) apresentou diâmetro médio de 0,37 µm. Um parâmetro adequado para eletrofiação foi capaz de produzir fibras ultrafinas de PMMA / PEI. (AU)


Assuntos
Microscopia Eletrônica de Varredura , Polimetil Metacrilato , Espectroscopia de Perda de Energia de Elétrons
8.
Rev. bras. cir. plást ; 35(2): 206-211, apr.-jun. 2020. ilus, tab
Artigo em Inglês, Português | LILACS-Express | LILACS | ID: biblio-1103834

RESUMO

A síndrome da embolia gordurosa (SEG) é definida como a presença de êmbolos gordurosos, não apenas no sistema pulmonar, como também na circulação sistêmica, com manifestações inflamatórias, neurológicas e cutâneas. Na cirurgia estética, atualmente, o material polimetilmetacrilato (PMMA) apresenta indicação para técnicas de preenchimento cutâneo, utilizado na forma injetável em pequenos procedimentos estéticos não incisionais, conhecidos como bioplastia. O presente estudo teve como objetivo fazer uma revisão sistemática de literatura para mostrar estudos clínicos que abordassem a ocorrência de síndrome da embolia gordurosa em pacientes que se submeteram a infiltração de PMMA (polimetilmetacrilato) na bioplastia. Mesmo com esgotamento de fontes e ampliação da pesquisa sistemática que seguiu os preceitos do protocolo PRISMA, a resposta foi de apenas um artigo que foi adicionado ao presente estudo. Infelizmente não há revisões ou estudos experimentais que contemplem a SEG na infiltração com PMMA. A maioria dos relatos disponibilizados é proveniente de lipoaspiração e correlacionados ao trauma ósseo quando citado o uso de PMMA. Esta revisão serve de alerta para os estudos e relatos não científicos sobre os riscos da utilização de PMMA na bioplastia, mas não se obteve relatos ou relacionados com a embolia gordurosa, potencialmente fatal.


Fat embolism syndrome (FES) is defined as the presence of fatty emboli, not only in the pulmonary system, but also in the systemic circulation, with inflammatory, neurological and cutaneous manifestations. Currently, in cosmetic surgery, the polymethylmethacrylate (PMMA) material is indicated for skin filling techniques used in injectable form in small non-incisional aesthetic procedures, known as bioplasty. The objective of this study was to carry out a systematic review of the literature to show clinical studies that addressed the appearance of fat embolism syndrome in patients who underwent PMMA (polymethylmethacrylate) infiltration in bioplasty. Even with the exhaustion of sources and the expansion of systematic research that followed the precepts of the PRISMA protocol, the answer was only one article that was added to the present study. Unfortunately, no reviews or experimental studies are looking at FES in PMMA infiltration. Most of the available reports are about liposuction and correlate with bone trauma when PMMA use is mentioned. This review serves as a wake-up call for nonscientific studies and reports on the risks of using PMMA in bioplasty, but no reports or articles were obtained related to life-threatening fat embolism.

9.
Mem. Inst. Invest. Cienc. Salud (Impr.) ; 18(1)abr. 2020. tab, ilus
Artigo em Espanhol | LILACS, BDNPAR | ID: biblio-1291898

RESUMO

Las resinas a base de polimetilmetacrilato (PMM) son una solución para la reposición de estructuras dentarias. Este material ha sido muy utilizado debido a su buena estética, pero las rugosidades, grietas y defectos de este material son propicios para la proliferación de microrganismos que podrían constituir un riesgo para la salud de los pacientes. Estudio observacional descriptivo de corte transversal, donde se tomaron muestras de provisorios de PMM de 20 pacientes de la cátedra de Clínica Integrada de Odontología de la Universidad Autónoma de Asunción. Los datos sobre el crecimiento de los microorganismos fueron anotados en planillas Excel para análisis estadísticos. De los 20 pacientes que participaron en esta investigación, 50% fueron de sexo femenino y 50% masculino, el promedio de edad fue de 32,35 años (DE±11,94). Se analizaron un total de 7 pónticos (6 pónticos de 3 piezas y 1 de 6 piezas) y 19 coronas unitarias, el tiempo de permanencia en boca fue de entre 4 a 20 semanas con una media de 8,6 semanas. El 65% de las muestras dio positivo al cultivo microbiológico. En algunas muestras se aislaron más de un género de microorganismos. Se aislaron 5 especies de bacterias Gram-negativas, la más frecuente fue K. pneumoniae con un 40%. Se aisló C. albicans en un 10% de las muestras. En el proceso de elección de los materiales para rehabilitación es fundamental considerar la situación global de cada paciente, pues exponerlos a un material con grandes capacidades retentivas de microrganismos conlleva un peligro


Polymethylmethacrylate (PMM) based resins are a solution for the replacement of dental structures. This material has been widely used due to its good aesthetics, but the roughness, cracks and defects of this material are propitious for the proliferation of microorganisms that could constitute a risk to the health of patients. This was a descriptive cross-sectional observational study, where samples of PMM provisionals were taken from 20 patients of the Department of Integrated Dental Clinic of the Autonomous University of Asunción. Data on the growth of microorganisms were recorded in Excel spreadsheets for statistical analysis. Of the 20 patients who participated in this research, 50% was female and 50% male, and the average age was 32.35 years (SD±11.94). Seven pontics (6 pontics of 3 pieces and 1 of 6 pieces) and 19 unit crowns were analyzed, the time spent in the mouth was between 4 to 20 weeks with an average of 8.6 weeks. Sixty-five percent of the samples tested positive in the microbiological culture. In some samples, more than one genus of microorganisms was isolated. Five species of Gram-negative bacteria were isolated, the most frequent was Klebsiella pneumoniae with 40%. Candida albicans was isolated in 10% of the samples. In the process of choosing materials for rehabilitation, it is essential to consider the overall situation of each patient, since exposing them to a material with high retention capacities of microorganisms carries a danger


Assuntos
Humanos , Masculino , Feminino , Adulto , Infecções por Bactérias Gram-Negativas , Polimetil Metacrilato , Candida albicans
10.
Dental press j. orthod. (Impr.) ; 25(2): 44-51, Mar.-Apr. 2020. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1133656

RESUMO

ABSTRACT Objective: To evaluate facial profile changes promoted by polymethyl methacrylate (PMMA) cement graft to reduce excessive gingival display due to hyperactivity of the elevator muscles of the upper lip during smiling. Methods: Eleven patients (all females, age range: 20 to 43 years) presenting gingival smile that were treated with PMMA cement grafts in a private clinic were selected for this retrospective study. Three angular and ten linear cephalometric facial profile measurements were performed preoperatively (baseline, T1) and at least 6 months postoperatively (T2). Differences between T1 and T2 were verified by Wilcoxon test, and the correlation between the thickness of the graft and facial profile changes was statistically evaluated by Spearman's Coefficient test. The significance level was set at p< 0.05. Results: The nasolabial angle (p= 0.03) and the labial component of the nasolabial angle showed statistically significant differences (p= 0.04), with higher values in T2. No correlations were found between the graft thickness and the statistically significant facial profile changes (p> 0.05). Conclusions: The PMMA bone cement graft projected the upper lip forward, thereby increasing the nasolabial angle without affecting the nasal component. No correlations between the graft thickness and the facial profile changes were detected.


RESUMO Objetivo: Avaliar as alterações do perfil facial promovidas pelo enxerto de cimento de polimetilmetacrilato (PMMA) para redução da exposição gengival excessiva devida à hiperatividade dos músculos elevadores do lábio superior durante o sorriso. Métodos: Onze pacientes (todos do sexo feminino, faixa etária de 20 a 43 anos) com sorriso gengival, tratados com enxerto de cimento de PMMA em clínica privada, foram selecionados para este estudo retrospectivo. Três medidas cefalométricas angulares e dez lineares do perfil facial foram realizadas no pré-operatório (T1) e com pelo menos seis meses de pós-operatório (T2). As diferenças entre T1 e T2 foram verificadas pelo teste de Wilcoxon, e a correlação entre a espessura do enxerto e as alterações do perfil facial foi avaliada estatisticamente pelo Coeficiente de Spearman. O nível de significância foi estabelecido em p< 0,05. Resultados: o ângulo nasolabial (p= 0,03) e o componente labial do ângulo nasolabial apresentaram diferenças estatisticamente significativas (p= 0,04), com maiores valores em T2. Não foram encontradas correlações estatisticamente significativas (p> 0,05) entre a espessura do enxerto e as alterações do perfil facial. Conclusões: O enxerto de cimento ósseo de PMMA projetou discretamente o lábio superior, aumentando o ângulo nasolabial sem afetar o componente nasal. Não foram detectadas correlações entre a espessura do enxerto e as alterações do perfil facial.


Assuntos
Humanos , Feminino , Adulto , Adulto Jovem , Sorriso , Cimentos Ósseos , Cefalometria , Estudos Retrospectivos , Gengiva , Lábio
11.
Acta odontol. Colomb. (En linea) ; 10(2)2020. ilus, ilus, ilus, ilus, ilus, ilus, ilus, ilus, ilus, ilus, ilus, ilus, ilus
Artigo em Espanhol | COLNAL, LILACS | ID: biblio-1123484

RESUMO

Introducción: los defectos del cráneo y las anomalías del hueso craneofacial que requie-ren reconstrucción son comunes en una variedad de procedimientos neuroquirúrgicos. Después de una craniectomía o de fracturas craneofaciales posteriores a traumatismos cráneoencefálicos, los pacientes pueden desarrollar defectos cosméticos importantes. Algunos de estos son la depresión de la piel y un defecto de hundimiento que lleva a una apariencia asimétrica de la cabeza, sin dejar de lado las repercusiones físicas, neu-rológicas y psicológicas que estas lesiones conllevan. La reconstrucción craneofacial y la craneoplastía tienen una larga historia, pero las nuevas técnicas quirúrgicas y una multitud de opciones de materiales han impulsado recientemente el avance en esta área. Los implantes de polimetilmetacrilato (PMMA) han demostrado ser estables, bio-compatibles, no conductores, radiotransparentes y de bajo costo. Es así que se pueden colocar y modificar fácilmente, con lo que se elimina la morbilidad del sitio donante. Presentación del caso: en este artículo presentamos un caso de craneoplastía de defec-to frontal, posterior a traumatismo, cuya reconstrucción fue realizada mediante una prótesis de polimetilmetacrilato (PMMA) en el Hospital General Xoco de la Cuidad de México. Conclusión: se reporta la reducción del tiempo quirúrgico, además de un costo de la prótesis accesible para el paciente; de esta manera, se obtuvieron resultados sa-tisfactorios y mejoras en el contorno estético facial, en tanto se permitió cobertura y protección para el tejido encefálico.


Introduction: Skull defects and craniofacial bone abnormalities that require reconstruction are common in a variety of neurosurgical procedures. After craniectomy or craniofacial fractures following cranioencephalic trauma, patients can develop important cosmetic defects, such as depression of the skin and a sunken flap that can lead to an asymmetrical appearance of the head, without neglecting the physical and psychological repercussions. neurological that these injuries carry. Craniofacial reconstruction and cranioplasty have a long history, but new surgical techniques and a multitude of material options have recently fueled progress in this area. Polymethylmethacrylate (PMMA) implants have proven to be stable, biocompatible, non-conductive, radiolucent, and inexpensive. They can be easily placed and modified and the morbidity of the donor site is eliminated. Clinical case: In this article, we present a case of frontal defect cranioplasty after trauma performed using a polymethylmethacrylate (PMMA) prosthesis at the General Hospital Xoco in Mexico City. Conslusion: The surgical time could be reduced, in addition to the cost of the prosthesis. It was accessible to the patient and obtained satisfactory results such as improvements in the facial aesthetic contour and obtained coverage and protection for the brain tissue.


Assuntos
Humanos , Polimetil Metacrilato , Lesões Encefálicas Traumáticas , Próteses e Implantes , Fratura do Crânio com Afundamento
12.
São José dos Campos; s.n; 2020. 94 p. il., graf., tab..
Tese em Português | BBO - Odontologia | ID: biblio-1150744

RESUMO

Este estudo visou sintetizar e caracterizar mantas não tecidas de nanofibras (NFs) do acrilonitrila butadieno estireno (ABS), poliamida 6 (PA6) e poliestireno (PS), e avaliar sua capacidade de ser utilizada como reforço no polimetilmetacrilato (PMMA). O ABS foi dissolvido em diclorometano e acetona, a PA6 pelo 1,1,1,3,3,3- Hexafluoro-2-propanol e o PS pela dimetilformamida, em uma concentração definida em estudo piloto. Após determinados os melhores parâmetros de eletrofiação (tensão contínua, razão de fluxo e distância agulha/anteparo) as amostras de cada grupo foram analisadas em microscopia eletrônica de varredura, análise de molhabilidade, análise de difratometria de raios X, espectroscopia de infravermelho por transformada de Fourier, diâmetro das fibras e resistência a tração. As NFs produzidas foram incluídas na área de tração dos corpos de prova em resina acrílica ativada termicamente (RAAT) conforme ISO1567, perfazendo 4 grupos (n=20), 1 controle (Grupo 1) e 3 experimentais (Grupo 2, RAAT+NF/ABS; Grupo 2, RAAT+NF/PA6; Grupo 4, RAAT+NF/PS), para ensaio de flexão três pontos para analisar suas propriedades mecânicas, como: módulos de elasticidade e resistência a flexão. De acordo com os testes de caracterização, as mantas se apresentaram hidrofóbicas, não houve mudança de sua estrutura polimérica, concluindo-se então que a técnica da eletrofiação foi promissora na síntese de mantas de NFs. A variação dos parâmetros afetou diretamente a morfologia, resultando em fibras uniformes, volumosas e sem defeitos (beads). Os Grupos 3 e 4 (RAAT+NF/PA6 e RAAT+NF F/PS) apresentaram um maior módulo elástico, conferindo maior rigidez ao material (AU)


This study aimed to synthesize and characterize non-woven blankets of acrylonitrile butadiene styrene (ABS), polyamide 6 (PA6) and polystyrene (PS) nanofibers (NFs), and to evaluate their ability to be used as reinforcement in polymethyl methacrylate (PMMA). ABS was dissolved in dichloromethane and acetone, PA6 by 1,1,1,3,3,3- hexafluoro-2-propanol and PS by dimethylformamide at a concentration defined in a pilot study. After determining the best electrospun parameters (continuous voltage, flow rate and needle/shield distance) the samples from each group were analyzed by scanning electron microscopy, wettability analysis, X-ray diffraction analysis, Fourier transform infrared spectroscopy, fiber diameter and tensile strength. The NFs produced were included in the tensile area of the thermally activated acrylic resin (RAAT) specimens according to ISO1567, making up 4 groups (n = 20), 1 control (Group 1) and 3 experimental (Group 2, RAAT+NF/ABS; Group 3, RAAT+NF/PA6 and Group 4 (RAAT+NF/PS), for three point bending test to analyze their mechanical properties, as: modules of elasticity and flexural strength. According to the characterization tests, the blankets were hydrophobic, there was no change in their polymeric structure, concluding that the electrospinning technique was promising in the synthesis of NFs blankets. The parameters variation affected directly in the morphology, resulting in uniform, bulky and without defects (beads) NFs blankets. The Groups 3 and 4 (NF/PA6+RAAT and NF/PS+RAAT) presented a superior elastic modulus, therefore a superior rigidity(AU)


Assuntos
Polimetil Metacrilato/síntese química , Polímeros/efeitos adversos , Polimetil Metacrilato/administração & dosagem
13.
Odontol. vital ; (31): 11-18, jul.-dic. 2019. tab, graf
Artigo em Espanhol | LILACS, BBO - Odontologia | ID: biblio-1091422

RESUMO

Resumen Introducción: En la actualidad existen diversos tipos de materiales para la confección de placas bases, como procedimiento para la confección de prótesis dentales. La opción de la lámina de termoformado actualmente es de poco uso, el acrílico de autopolimerización es un material de uso diario en consulta. Objetivo: Comparar las técnicas de confección de placas bases, para determinar cuál de las dos brinda cualidades como menor tiempo de elaboración y menor deformidad. Materiales y métodos: Se seleccionaron por conveniencia 20 modelos de yeso totalmente edéntulos, a los cuales se registra tiempo de elaboración y se les aplican las mismas pruebas de laboratorio. Resultados: Las placas bases termoformadas presentan un tiempo medio de 7 minutos, mientras que las placas bases de acrílico de autopolimerización muestran un tiempo medio de 29 minutos, con base en los análisis de laboratorio la menor deformación se presenta en la placa base de acrílico de autopolimerización. Conclusión: El tiempo de elaboración de la placa base termoformable es menor, mientras que la deformación es mayor en comparación con la de la placa base de autopolimerización, y esta última a su vez, presenta mayor tiempo de elaboración que el de la placa base termoformable.


Abstract Introduction: Currently there are different types of materials for the preparation of base plates, as a procedure for the preparation of dental prostheses. The option of the thermoforming sheet, which is currently of little use, as well as, of self-curing acrylic, a material of daily use in consultation. Objective: To compare the techniques for making base plates, to determine which of the two provide qualities such as shorter processing time and less deformity. Materials and methods: 20 models of gypsum totally edentulous were selected for convenience, to which processing time is recorded and the same laboratory tests are applied. Results: The thermoformed base plates have an average time of 7 minutes, while the self-polymerized acrylic base plates have an average time of 29 minutes, based on the laboratory analysis the least deformation occurs in the acrylic base plate of autopolimerization. Conclusion: The time of preparation of the thermoformable base plate is less, while the deformation is greater compared to the base plate of self-polymerizatíon, the latter in turn, has a longer processing time than the thermoformable base plate.


Assuntos
Resinas Acrílicas/uso terapêutico , Prótese Dentária/instrumentação , Polimetil Metacrilato/uso terapêutico
14.
Rev. bras. ortop ; 54(4): 416-421, July-Aug. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1042417

RESUMO

Abstract Objective This study aims to evaluate, through biomechanical tests, the resistance and energy required for proximal femoral fracture in synthetic bones after removing cannulated screws shaped as an inverted triangle, comparing the obtained results to those of a reinforcement technique with polymethylmethacrylate (PMMA) as bone cement. Methods Twenty synthetic bones were used: 10 units for the control group (CG), 5 units for the test group without reinforcement (TGW/O), and 5 units for the test group using a reinforcement technique with PMMA (TGW). The biomechanical analysis simulated a fall on the large trochanter using a servo-hydraulic machine. Results All TGW/O and CG specimens had a basicervical fracture. Three TGW specimens presented a basicervical fracture, and two suffered a fracture near the fixation point of the device (femoral diaphyseal region), with one of thembeing associated with a femoral neck fracture. A mean PMMA volume of 8.2 mL was used to fill the 3 screw holes in the TGWgroup. According to the one-way analysis of variance (ANOVA) and the Tukey multiple comparisons tests at a 5% level, the TGW presented a statistically significant difference when compared with the other groups in all parameters: maximal load (p = 0.001) and energy until fracture (p = 0.0001). Conclusion The simple removal of the cannulated screws did not reduce significantly the maximum load and energy for fracture occurrence, but the proximal femoral reinforcement with PMMA significantly increased these parameters, modifying the fracture pattern.


Resumo Objetivo Avaliar, pormeio de ensaio biomecânico, a resistência e a energia necessária para ocorrência de fratura do fêmur proximal em osso sintético após retirada de parafusos canulados em forma de triângulo invertido e comparar os resultados obtidos com técnica de reforço utilizando polimetilmetacrilato (PMMA). Métodos Foramutilizados 20 ossos sintéticos: 10 unidades para o grupo controle; 5 o grupo teste sem reforço, sem preenchimento após a retirada dos parafusos canulados, e 5 o para grupo teste com reforço com PMMA. A análise biomecânica foi realizada simulando queda sobre o grande trocânter utilizando máquina servo-hidráulica. Resultados Todos os corpos de prova dos grupos controle e sem cimento apresentaram fratura baso-cervical. No grupo teste com preechimento, três corpos de prova apresentaram fratura baso-cervical, enquanto que dois deles apresentaram fratura na parte próxima ao ponto de fixação no dispositivo (região diafisária do fêmur), sendo um deles associado a fratura do colo femoral. Foi utilizada uma média de 8.2 ml de polimetilmetacrilato no preenchimento dos três pertuitos do grupo com preenchimento. Segundo a análise de variância (ANOVA, na sigla em inglês) para um fator e o teste de comparações múltiplas de Tukey, ao nível de 5%, o grupo com cimento apresentou diferença significativa em relação aos outros grupos em todos os parâmetros. Conclusão A simples retirada dos parafusos canulados não apresentou redução significativa da carga máxima e da energia necessárias para a ocorrência de fratura; porém, o reforço do fêmur proximal com polimetilmetacrilato aumentou significativamente esses parâmetros, causando mudanças no padrão fraturário.


Assuntos
Osteoporose , Polimetil Metacrilato , Fraturas do Fêmur , Fraturas do Quadril
15.
RGO (Porto Alegre) ; 66(3): 267-273, July-Sept. 2018. graf
Artigo em Inglês | LILACS | ID: biblio-984900

RESUMO

ABSTRACT Cranioencephalic trauma which results in extensive edema and / or bruising usually requires surgical treatment through a greater withdrawal of the bone portion. Thus, the absence of bone tissue implies the lack of protection of the brain tissue or even compromises the esthetics especially when located in the frontal or frontoparietal region. The purpose of this case report is to describe a treatment option for head trauma, through the prefabricated part by obtaining the skull model. These bone faults can be reconstructed either by the direct method using polymethylmethacrylate directly on the defects or by means of pre-made pieces such as prototyping or from the skull model. Although other techniques have many good points, some show certain drawbacks, from storage conditions below abdominal fat, preheating due to the release of heat during the high polymerization reaction or the high cost when they are prototyped. The technique described in this work reports its simple performance, eliminating the risk of local heating, allows prior sterilization in autoclave, it is biocompatible, allows perfect anatomical recovery, easy placement, low cost, also highlighs the advantage of the bucomaxillofacial surgeon's performance due to the familiarization with the relevant head and neck procedures. Clinical and tomographic examination after 24 months of treatment showed stability of the polymethylmethacrylate plate, adhesions to the bone margins, and absence of tissue alterations.


RESUMO Os traumatismos cranioencefálicos que resultam em extensos edemas e ou hematomas normalmente, requerem tratamentos cirúrgicos por meio de uma retirada maior de porção óssea. Deste modo, a ausência do tecido ósseo implica na falta de proteção do tecido cerebral ou até mesmo comprometer a estética especialmente, quando localizadas na região frontal ou frontoparietal. O objetivo deste relato de caso é descrever uma opção de tratamento para os traumatismos cranioencefálicos, por meio da peça pré-fabricada mediante a obtenção do modelo do crânio. Estas falhas ósseas podem ser reconstruídas tanto pelo método direto utilizando o polimetilmetacrilato diretamente sobre as falhas ou por meio das peças pré-confeccionadas como a prototipagem ou a partir do modelo do crânio. Embora outras técnicas apresentem muitos pontos positivos, algumas mostram determinados inconvenientes, desde condição de armazenamento abaixo da gordura abdominal, aquecimento prévio devido a liberação de calor durante a reação de alto polimerização ou o alto custo quando são prototipadas. A técnica neste trabalho descrita relata sua facilidade de execução, elimina o risco do aquecimento local, permite a prévia esterilização em autoclave, é biocompatível, permite a perfeita recuperação anatômica, fácil colocação, baixo custo, ressaltando ainda a vantagem da atuação do cirurgião bucomaxilofacial devido sua familiarização com os procedimentos pertinentes a cabeça e pescoço. Em exame clínico e tomográfico após 24 meses do tratamento, observa-se estabilidade da placa de polimetilmetacrilato, aderências às margens ósseas, e ausência de alterações tissulares.

16.
Acta ortop. bras ; 26(4): 231-235, July-Aug. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-973551

RESUMO

ABSTRACT Objective: To evaluate the mechanical behavior of the proximal end of the femur submitted to the X-shaped polymethylmethacrylate (PMMA) reinforcement technique. Methods: Fifteen synthetic femurs, with a Nacional® density of 10 PCF, were divided into two groups: the DX group, with 5 units that were submitted to PMMA reinforcement, and the DP group, with 10 units, which were evaluated intact. The volume of PMMA required, the maximum load, and the absorbed energy to fracture were analyzed by means of a static mechanical bending test simulating a fall on the greater trochanter. Results: A mean of 6 ml of PMMA was used to model the X-reinforcement; it was observed that the DX group presented significantly higher maximum load (median = 1553 N, p = 0.005) and absorbed energy to fracture (median = 9.7 J; p = 0.050) than the DP group (median = 905 N and 6.6 J). Conclusion: X-reinforcement of the proximal end of synthetic femurs showed a statistically significant increase in the maximum load and absorbed energy to fracture in the mechanical assay when compared to the control group. Level of Evidence III, Experimental study.


RESUMO Objetivo: Avaliar o comportamento mecânico da extremidade proximal do fêmur submetido à técnica de reforço com polimetilmetacrilato (PMMA) em forma de X. Métodos: Foram utilizados 15 fêmures sintéticos, com densidade de 10 PCF da Nacional®, divididos nos grupos DX, com 5 unidades submetidas ao reforço com PMMA, e DP com 10 unidades, avaliados com sua integridade intacta. Foram analisados o volume de PMMA necessário, os valores da carga máxima e a energia absorvida até a fratura por meio de ensaio mecânico estático de flexão, simulando queda sobre o trocanter maior. Resultados: Foram usados em média 6 ml de PMMA para a modelagem do reforço em X e observou-se que o grupo DX apresentou carga máxima (mediana = 1553 N; p = 0,005) e energia absorvida até fratura (mediana = 9,7 J; p = 0,050) significativamente maior que o grupo DP (mediana = 905 N e 6,6 J). Conclusão: O reforço em X da extremidade proximal de fêmures sintéticos apresentou incremento estatisticamente significativo da carga máxima e energia absorvida até a fratura no ensaio mecânico em comparação com o grupo controle. Nível de evidência III, Estudo experimental.

17.
Cir Cir ; 86(3): 289-295, 2018.
Artigo em Espanhol | MEDLINE | ID: mdl-29950735

RESUMO

INTRODUCCIÓN: Los defectos craneales secundarios a traumatismos son frecuentes. Por lo común se reparan de forma secundaria por sintomatología como el síndrome del paciente trepanado, por protección cerebral y por el aspecto cosmético. Históricamente se han utilizado diversos materiales para la reconstrucción. CASOS CLÍNICOS: Se presentan cinco casos de pacientes reconstruidos con implantes personalizados de polieteretercetona (PEEK) o polimetilmetacrilato poroso (PMMA). Las localizaciones afectaron el frontal, el borde orbitario superior y el techo orbitario en cuatro casos, y la porción lateral del frontal, la zona temporoparietal y el borde del occipital en un caso. La reconstrucción en cuatro pacientes fue entre 6 y 12 meses después de la lesión, y en un caso después de 25 años. En dos casos se requirió expansión tisular antes de colocar el implante. RESULTADOS: Cuatro pacientes evolucionaron favorablemente, con mejoría de los síntomas neurológicos, forma y contorno adecuados, así como un proceso de cicatrización adecuada de los colgajos de piel cabelluda. Un paciente presentó infección por Staphylococcus aureus, atribuida a la presencia de un mucocele y una fístula de la vía aérea a la cavidad craneal, lo que hizo necesario retirar el implante. CONCLUSIONES: Los implantes personalizados son un recurso útil para defectos óseos craneales. Brindan resultados satisfactorios desde el punto de vista funcional y cosmético. Deben tomarse precauciones respecto al tratamiento de las lesiones que afecten el seno frontal, para evitar la comunicación entre la vía aérea y la cavidad craneal. INTRODUCTION: Cranial defects due to trauma are frequent. They are usually repaired in a secondary fashion due to features such as syndrome of the trephined, for brain protection and for cosmetic purposes. Historically, various materials have been used for reconstruction. CASE REPORTS: Five cases of patients reconstructed with customized polyetheretherketone (PEEK) o polymethyl methacrylate (PMMA) implants are presented. Defects involved the frontal bone, superior orbital rim and orbital roof in four cases, and the lateral area of the frontal bone, the temporoparietal area and the border of the occipital bone in one. In four patients, reconstruction took place between 6 and 12 months after the injury; in one patient, after 25 years. Two cases required tissue expansion before placing the implant. RESULTS: Four patients evolved favorably, with improvement in neurologic symptoms and adequate shape and contour, plus adequate healing of the scalp flaps. One patient had an infection due to Staphylococcus aureus, attributed to a mucocele and fistula between the airway and the cranial cavity, leading to removal of the implant. CONCLUSIONS: Customized implants are a useful resource for cranial defects. They offer satisfactory results, both functional and cosmetic. Precautions should be taken in treating injuries that involve the frontal sinus, to ensure there is no communication between the airway and the cranial cavity.


Assuntos
Procedimentos de Cirurgia Plástica/métodos , Próteses e Implantes , Crânio/lesões , Crânio/cirurgia , Adolescente , Adulto , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
18.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-29157990

RESUMO

INTRODUCTION: The increasing antimicrobial resistance is promoting the addition of antibiotics with high antistaphylococcal activity to polymethylmethacrylate (PMMA), for use in cement spacers in periprosthetic joint infection. Linezolid and levofloxacin have already been used in in-vitro studies, however, rifampicin has been shown to have a deleterious effect on the mechanical properties of PMMA, because it inhibits PMMA polymerization. The objective of our study was to isolate the rifampicin during the polymerization process using microencapsulation techniques, in order to obtain a PMMA suitable for manufacturing bone cement spacers. MATERIAL AND METHOD: Microcapsules of rifampicin were synthesized with alginate and PHBV, using Rifaldin®. The concentration levels of rifampicin were studied by UV-visible spectrophotometry. Compression, hardness and setting time tests were performed with CMW®1 cement samples alone, with non-encapsulated rifampicin and with alginate or PHBV microcapsules. RESULTS: The production yield, efficiency and microencapsulation yield were greater with alginate (P = .0001). The cement with microcapsules demonstrated greater resistance to compression than the cement with rifampicin (91.26±5.13, 91.35±6.29 and 74.04±3.57 MPa in alginate, PHBV and rifampicin, respectively) (P = .0001). The setting time reduced, and the hardness curve of the cement with alginate microcapsules was similar to that of the control. DISCUSSION AND CONCLUSIONS: Microencapsulation with alginate is an appropriate technique for introducing rifampicin into PMMA, preserving compression properties and setting time. This could allow intraoperative manufacturing of bone cement spacers that release rifampicin for the treatment of periprosthetic joint infection.


Assuntos
Antibacterianos/farmacocinética , Cimentos Ósseos/química , Composição de Medicamentos/métodos , Polimetil Metacrilato/química , Infecções Relacionadas à Prótese/prevenção & controle , Rifampina/farmacocinética , Alginatos/química , Antibacterianos/química , Cápsulas , Ácido Glucurônico/química , Ácidos Hexurônicos/química , Humanos , Teste de Materiais , Polimerização , Rifampina/química
19.
Rio de Janeiro; s.n; s.n; 2018. 62 p. tab, ilus, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-964018

RESUMO

O objetivo principal do presente estudo, considerando a importância do controle do biofilme, foi avaliar in situ a ação antimicrobiana e análise elementar da incorporação de diacetato de clorexidina(CHX) em resinas acrílicas a base de PMMA. Além disso, avaliar ex vivo o mecanismo de lixiviação da clorexidina por até 14 dias. Primeiramente, foram recrutados 32 indivíduos para utilização de dispositivos acrílicos intraorais palatinos por 24 horas contendo 6 corpos de prova(CPs), sendo subdivididos em 2 grupos: com clorexidina (1%) e sem CHX. A avaliação da atividade antimicrobiana foi realizada por meio de contagem de colônias de microorganismos totais e Estreptococos do grupo mutans. Então, os grupos foram avaliados estatisticamente pelo teste de wilcoxon. A análise estatística aplicada foi o teste de Wilcoxon. No segundo teste, foi feita a análise elementar dos CPs(n=10) por meio das médias das intensidade dos elementos, antes e após o uso do dispositivo, por meio da fluorescência de raio X. Ao final, foi avaliado ex vivo a liberação de clorexidina cumulativa, em meio fechado contendo saliva dos indivíduos(n=5) por até 14 dias, através da ressonância magnética nuclear (RMN). As análises estatísticas da RMN, foram avaliadas pelo programa AMIX e metaboloanalyst. Os resultados mostraram, que para atividade antimicrobiana não houve diferença estatística (p>0,05) entre os grupos. Foi detectado a presença da molécula de clorexidina, antes e após a inserção dos CPs com CHX na cavidade bucal. Já para liberação de clorexidina, foi detectada a droga ao longo de 14 dias em meio fechado para a grupo teste, com liberação maior nas primeiras 24 horas. Conclui-se que, foi comprovada a presença do fármaco na resina acrílica após 24 horas em meio bucal, e seu mecanismo de lixiviação no meio fechado por até 14 dias. Porém, não foram encontrados resultados que confirmem a presença de um potencial antimicrobiano do fármaco, nas concentrações utilizadas nos corpos de prova in situ em 24 horas.


The main objective of the present study, considering the importance of biofilm control, was to evaluate in situ the antimicrobial action and elemental composition of the incorporation of chlorhexidine diacetate (CHX) in acrylic resins based on PMMA. In addition, ex vivo evaluation of the chlorhexidine release mechanism to 14 days. Firstly, 32 individuals were recruited for 24-hour palatal intraoral acrylic devices containing 6 test specimens (SPs), divided into 2 groups: with chlorhexidine (1%) and without CHX. The evaluation of the antimicrobial activity was performed by colonies count of total microorganisms and streptococci mutans group. Then, the groups were statistically evaluated by the wilcoxon test. The statistical analysis applied was the Wilcoxon test. In the second test, elemental analysis of the SPs (n = 10) was done by means of the means intensity of the elements, before and after the use of the device, by X-ray fluorescence. At the end, the release was evaluated ex vivo of cumulative chlorhexidine in a becker containing saliva of the individuals (n = 5) for 14 days, through nuclear magnetic resonance (NMR). The NMR analyzes were evaluated by AMIX and metaboloanalyst. The results showed that for antimicrobial activity there was no statistical difference (p> 0.05) between the groups. The presence of the chlorhexidine molecule was detected before and after the insertion of SPs with CHX in the oral cavity. As for chlorhexidine release, the drug was detected over 14 days in a closed medium for the test group, with a greater release in the first 24 hours. It was concluded that the presence of the drug in the acrylic resin after 24 hours in oral cavity was verified, and its release mechanism in the closed local for 14 days. However, no results were found to confirm the presence of an antimicrobial potential of the drug at the concentrations used in the in situ test specimens in 24 hours


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Resinas Acrílicas , Clorexidina/farmacologia , Polimetil Metacrilato , Placa Dentária/prevenção & controle , Anti-Infecciosos Locais/farmacologia , Streptococcus mutans/efeitos dos fármacos , Espectroscopia de Ressonância Magnética , Estatísticas não Paramétricas , Fluorescência
20.
Pesqui. vet. bras ; 37(12): 1491-1498, dez. 2017. ilus
Artigo em Português | LILACS, VETINDEX | ID: biblio-895381

RESUMO

As afecções ortopédicas com perda de tecido ósseo são um desafio não só na medicina veterinária mas também na medicina humana. Analisou a interface entre compósito, constituído de esferas de quitosana e polimetilmetacrilato em falha óssea (leito receptor) de tíbia de coelhos, por meio de técnica radiológica, avaliação macroscópica e pela microscopia eletrônica de varredura, em diferentes tempos. Foram utilizados 12 coelhos adultos da raça Nova Zelândia, divididos em quatro Grupos Experimentais (E1, n=3; E2, n=3; E3, n=3 e E4, n=3), que tiveram as falhas ósseas das tibiais direitas preenchidas com compósito, e avaliadas no pós-operatório imediato, aos 30, 60 e 90 e 120 dias. Dos compósitos implantados nas tíbias de coelhos, apenas dois permaneceram em seus leitos receptores, enquanto que os demais se encontravam encapsulados no tecido subcutâneo. As esferas de quitosana, presentes nas superfícies dos biomateriais implantados, que mantiveram contato direto com o leito receptor de tíbias de coelhos apresentavam-se preservadas e não integraram ao tecido ósseo. Diante disso, para melhor compreensão do comportamento da quitosana como substituto ósseo, novas pesquisas serão necessárias.(AU)


Orthopedic diseases with bone loss are challenging in both veterinary and human medicine. The aim of this investigation was to analyze and compare the reactions at the interface between the composite, made of chitosan and polymethylmethacrylate, and the bone defect (receptor site) of the rabbits tibia through radiological and microscopic techniques and by scanning electron microscopy, in different periods. Twelve adult New Zealand rabbits were divided into four experimental groups (E1, n=3; E2, n=3; E3, n=3 and E4, n=3), which had the right tibial bone defects filled with the composite, and evaluated in the immediate postoperative, 30, 60, 90 and 120 days. Composite implanted in the tibia of rabbits, only two remained in their beds receivers, while the remaining were encapsulated in the subcutaneous tissue. Spheres of chitosan present in the biomaterial that has been deployed and were in direct contact with the bone defect, were preserved, however, were not integrated into the bone tissue. Therefore, to understand the behavior of chitosan as a bone substitute, further research is needed.(AU)


Assuntos
Animais , Coelhos , Tíbia/cirurgia , Fraturas da Tíbia/veterinária , Resinas Compostas , Substitutos Ósseos/análise , Polimetil Metacrilato , Quitosana
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...